Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Chinese Journal of Microsurgery ; (6): 36-39, 2013.
Article in Chinese | WPRIM | ID: wpr-431386

ABSTRACT

Objective Comparing the clinical effect between Cinepazide Maleate and low Molecular weight Dextran,to the one which is more effective,safer and less unhealthy to patients after digital replantation.Methods From April 2010 to April 2012 in our hospital during single finger replantation patients,the observation group 120 cases of postoperative to Cinepazide Maleate injection 320mg/d intravenous drip,the control group of 120 cases treated with low Molecular Dextran 500ml/d IVGTT.Results The effective rate of observe group and control group was 96.67% and 92.50%,respectively.The difference between the two groups was too small to have statistically significant difference (P > 0.05),but the adverse effect of treatment group was only 5.8%,much lower than 14.17% in control group however with the statistically significant difference (P <0.05).Conclusion Cinepazide Maleate Injection and low Molecular weight Dextran both have apparent effect in patients after digital replantation surgery.Both of them significantly improved microcirculation,enhanced the survival rate of replantation.However Cinepazide Maleate injection has fewer adverse effects,which is one of idea auxiliary medicine and deserved more extensive clinic application in currently microsurgery.

2.
Chinese Journal of Practical Nursing ; (36): 28-30, 2012.
Article in Chinese | WPRIM | ID: wpr-423751

ABSTRACT

Objective To develop an intelligent cabinet with constant temperature and adjustable height,which is safer,more scientific and comfortable for heat preservation after surgical operation.Methods According to the demands of microscopic surgery we analyzed the disadvantages of existing equipment in order to seek new materials to solve the current problems.Results Using nanometer electric heating film to control temperature at 30~35 ℃ and adjust temperature in this range.Moreover debugging angle of stainless steel adjustable upholder at 0~45°.Conclusions Nanometer electric heating film is a kind of high safety,reliability and strong stability heating material and can be used for the microscopic surgery insulation.Adjustable lifting upholder makes limbs more comfortable with freely height.It shows that setting temperature at 30~31℃,angel value at 20~25°would be relatively suitable after our experiment.

SELECTION OF CITATIONS
SEARCH DETAIL